C00581 | resp. to external fault, C00582 | resp. to heatsink temp. > c00122, C00583 | resp. to filter kty overtemp – Lenze E94ARNE Regenerative power supply User Manual

Page 315: C00584 | resp. to filter temp. > c00121, C00581, C00583, C00584, C00582

Advertising
background image

EDS94ARNExxxx EN 2.3 - 06/2014

L

315

9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C00581

C00581

C00582

C00583

C00584

Parameter | Name:

C00581 | Resp. to external fault

Data type: UNSIGNED_32

Index: 23994

d

= 5DBA

h

Response to an external error

Drive interface

Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble
4 Warning locked
5 Warning
6 Information
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00582 | Resp. to heatsink temp. > C00122

Data type: UNSIGNED_32

Index: 23993

d

= 5DB9

h

Response if heatsink temperature > variable limit temperature (

C00122

).

Selection list

(Lenze setting printed in bold)

1 Fault
5 Warning
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00583 | Resp. to filter KTY overtemp.

Data type: UNSIGNED_32

Index: 23992

d

= 5DB8

h

Response if filter temperature > fixed temperature limit.
Selection list

(Lenze setting printed in bold)

1 Fault
5 Warning
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00584 | Resp. to filter temp. > C00121

Data type: UNSIGNED_32

Index: 23991

d

= 5DB7

h

Response if filter temperature > variable limit temperature (

C00121

).

Selection list

(Lenze setting printed in bold)

1 Fault
5 Warning
0 No response

Read access  Write access  CINH  PLC STOP  No transfer