C00613 | resp. to can heartbeat error, C00614 | resp. to can life guarding error, C00615 | resp. to imp. device config – Lenze E94ARNE Regenerative power supply User Manual

Page 320: C00614, Is initiated (lenze se, C00613/1, For the respective producer in, Go to, C00615/2, C00615/3

Advertising
background image

9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C00613

320

L

EDS94ARNExxxx EN 2.3 - 06/2014

C00613

C00614

C00615

Parameter | Name:

C00613 | Resp. to CAN heartbeat error

Data type: UNSIGNED_8

Index: 23962

d

= 5D9A

h

Response if the corresponding heartbeat telegram is not received.

"CAN on board" system bus: heartbeat protocol

Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble
4 Warning locked
5 Warning
6 Information
0 No response

Subcodes

Lenze setting

Information

C00613/1

0: No response

Response to non-received telegram for monitoring entry

1 ... 32

C00613/...
C00613/32

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00614 | Resp. to CAN life guarding error

Data type: UNSIGNED_8

Index: 23961

d

= 5D99

h

Response of slave if node guarding request is not received.

"CAN on board" system bus: node guarding protocol

Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble
4 Warning locked
5 Warning
6 Information
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00615 | Resp. to imp. device config.

Data type: UNSIGNED_32

Index: 23960

d

= 5D98

h

Selection list

1 Fault
4 Warning locked
6 Information
0 No response

Subcodes

Lenze setting

Information

C00615/1

0: No response

Reserved

C00615/2

1: Fault

Resp. to imp. module in MXI1

C00615/3

1: Fault

Resp. to imp. module in MXI2

C00615/4

0: No response

Reserved

C00615/5

0: No response

Reserved

Read access  Write access  CINH  PLC STOP  No transfer