9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C00367

C00367

C00368

C00369

Parameter | Name:

C00367 | CAN SYNC Rx identifier

Data type: UNSIGNED_32

Index: 24208

d

= 5E90

h

Identifier with which the sync slave is to receive sync telegrams.

• Mapping of the CANopen object

I-1005

(see DS301 V4.02).

"CAN on board" system bus: sync telegram

Setting range

(min. value | unit | max. value)

Lenze setting

0

2047 128

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00368 | CAN SYNC Tx identifier

Data type: UNSIGNED_32

Index: 24207

d

= 5E8F

h

Identifier with which the sync master is to send sync telegrams.

• Mapping of the CANopen object

I-1005

(see DS301 V4.02).

"CAN on board" system bus: sync telegram

Setting range

(min. value | unit | max. value)

Lenze setting

0

2047 128

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00369 | CAN SYNC transmit cycle time

Data type: UNSIGNED_16

Index: 24206

d

= 5E8E

h

Cycle in which the sync master is to send sync telegrams.

• When the setting "0 ms" (Lenze setting) is selected, no sync telegrams are generated.

• Mapping of the CANopen object

I-1006

(see DS301 V4.02).

"CAN on board" system bus: sync telegram

Setting range

(min. value | unit | max. value)

0

ms

65535

Subcodes

Lenze setting

Information

C00369/1

0 ms

Transmission cycle time for CAN on board

C00369/2

0 ms

Transmission cycle time for CAN module in MXI1/MXI2

C00369/3

0 ms

- (no meaning)

Read access  Write access  CINH  PLC STOP  No transfer