C00591 | resp. to can-rpdox error, C00594 | resp. to failure t. sensor filter, C00595 | resp. to can bus off – Lenze E94ARNE Regenerative power supply User Manual

Page 317: C00591/1, C00591/2, C00591/3, C00591/4, C00595, C00594

Advertising
background image

EDS94ARNExxxx EN 2.3 - 06/2014

L

317

9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C00591

C00591

C00594

C00595

Parameter | Name:

C00591 | Resp. to CAN-RPDOx error

Data type: UNSIGNED_8

Index: 23984

d

= 5DB0

h

Response if the corresponding CAN RPDO has not been received within the configured time or with the configured

sync.

"CAN on board" system bus

Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble
4 Warning locked
5 Warning
6 Information
0 No response

Subcodes

Lenze setting

Information

C00591/1

0: No response

Response to non-received RPDO1 ... RPDO4

C00591/...
C00591/4

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00594 | Resp. to failure t. sensor filter

Data type: UNSIGNED_32

Index: 23981

d

= 5DAD

h

Response to filter temperature sensor error.

• The response to a too high filter temperature via PTC input T1/T2 can be selected in

C00585

.

Selection list

(Lenze setting printed in bold)

1 Fault
5 Warning
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00595 | Resp. to CAN bus OFF

Data type: UNSIGNED_8

Index: 23980

d

= 5DAC

h

Response if CAN node switches to the bus off state.

"CAN on board" system bus

Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble
4 Warning locked
5 Warning
6 Information
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Advertising