Diagnostics & fault analysis error messages – Lenze E94ARNE Regenerative power supply User Manual

Page 206

Advertising
background image

9400 regenerative power supply module | Parameter setting

Diagnostics & fault analysis

Error messages

206

L

EDS94ARNExxxx EN 2.3 - 06/2014

0x006a0006

6946822

IdleTask: Overflow

Fault

-

0x00790000

7929856

Incorrect device command transfer

System fault

-

0x00680012

6815762

Incorrect memory module

System fault

-

0x00680013

6815763

Incorrect safety module

System fault

-

0x00770011

7798801

Inside the device: Fan is defect

Fault

C00611

0x0077000b

7798795

Inside the device: Thermal detector is defect

Fault

C00588

0x007b0034

8060980

Internal communication error (DMA)

System fault

-

0x007b0014

8060948

Internal communication error (host MCTRL)

System fault

-

0x007b0036

8060982

Internal communication error (MCTRL host)

System fault

-

0x00690009

6881289

Internal error (event mechanism)

System fault

-

0x0069000a

6881290

Internal error (event mechanism)

System fault

-

0x0069000d

6881293

Internal error (file system lifetime)

Warning

-

0x00690002

6881282

Internal error (LDS instance data)

System fault

-

0x00690003

6881283

Internal error (LDS tasks)

System fault

-

0x00690001

6881281

Internal error (memory area - logbook)

System fault

-

0x00690006

6881286

Internal error (message memory)

System fault

-

0x00690007

6881287

Internal error (message queue)

System fault

-

0x00690008

6881288

Internal error (name data base)

System fault

-

0x0069000b

6881291

Internal error (semaphores)

System fault

-

0x0069000c

6881292

Internal error (semaphores)

System fault

-

0x00690004

6881284

Internal error (storage blocks)

System fault

-

0x00690005

6881285

Internal error (task queue)

System fault

-

0x00910004

9502724

Internal error: See C00180

System fault

-

0x00910005

9502725

Internal error: See C00180

System fault

-

0x00910006

9502726

Internal error: See C00180

System fault

-

0x00910008

9502728

Internal error: See C00180

Fault

-

0x00910009

9502729

Internal error: See C00180

Fault

-

0x00900001

9437185

Lenze setting loaded

Information

-

0x00900004

9437188

Loading of Lenze setting failed

Fault

-

0x00650000

6619136

Logbook: Overflow

Information

-

0x00650001

6619137

Logbook: Reset (read error)

Information

-

0x00650002

6619138

Logbook: Reset (version error)

Information

-

0x007b0049

8061001

Mains not connected

Trouble

-

0x007b0045

8060997

Mains voltage 10% too high

Warning

-

0x007b0043

8060995

Mains voltage 10% too low

Warning

-

0x007b0046

8060998

Mains voltage 15% too high

Fault

-

0x007b0044

8060996

Mains voltage 15% too low

Fault

-

0x00910001

9502721

Mains voltage is switched off

Information

-

0x00910000

9502720

Mains voltage is switched on

Information

-

0x00680017

6815767

Memory module has been changed

Information or warning locked if

the hardware type has changed

as well.

-

0x00680006

6815750

Memory module has been removed

System fault

-

0x00680002

6815746

Memory module is defect or missing

Fault

-

0x0068000c

6815756

Memory module is defect or missing

System fault

-

0x00650003

6619139

Memory module is missing

Information

-

0x0068001c

6815772

Memory module: Faulty file system

Fault

-

0x007c0000

8126464

Memory module: File system has been formatted

Information

-

0x007c0001

8126465

Memory module: File system has been restored

Information

-

0x008c0017

9175063

MXI1: CAN module is missing or incompatible

Fault

-

0x008c0011

9175057

MXI1: Ethernet module is missing or incompatible

Fault

-

0x008c0015

9175061

MXI1: ICM module is missing or incompatible

Fault

-

Error number

Error message

Response

Adjustable in

hex

dec

(Lenze setting)

Advertising