9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C00173

C00173

C00175

C00176

C00177

C00178

C00179

Parameter | Name:

C00173 | Mains voltage

Data type: UNSIGNED_8

Index: 24402

d

= 5F52

h

Adaptation of the DC bus voltage thresholds

• Check during commissioning and adapt, if necessary.

• All drive components connected to the DC bus must have the same thresholds.

• For selection 0 ... 3, the undervoltage threshold is firmly defined depending on the device type (see "Rated data"

chapter in the Hardware Manual).

Note: Altering this setting also has an impact on the permissible device utilisation!

In the chapter "Rated data" of the Hardware Manual, the device types and their permissible utilisation at different

mains voltages and switching frequencies are specified.
Selection list

(Lenze setting printed in bold)

Information

0 230 V

Operation on 230 V mains

• Undervoltage threshold is firmly defined.

• Overvoltage threshold = 400 V

• Brake chopper threshold = 390 V

1 400/415 V

Operation on 400 V mains/415 V mains

• Undervoltage threshold is firmly defined.

• Overvoltage threshold = 800 V

• Brake chopper threshold = 725 V

2 460/480 V

Operation on 460 V mains/480 V mains

• Undervoltage threshold is firmly defined.

• Overvoltage threshold = 800 V

• Brake chopper threshold = 765 V

3 500 V

Operation on 500 V mains

• Undervoltage threshold is firmly defined.

• Overvoltage threshold = 800 V

• Brake chopper threshold = 790 V

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00175 | Service code

Data type: UNSIGNED_32

Index: 24400

d

= 5F50

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C00176 | Service code

Data type: UNSIGNED_32

Index: 24399

d

= 5F4F

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C00177 | Service code

Data type: UNSIGNED_32

Index: 24398

d

= 5F4E

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C00178 | Elapsed hour meter

Data type: UNSIGNED_32

Index: 24397

d

= 5F4D

h

Display range

(min. value | unit | max. value)

0

s

4294967295

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00179 | Power-on time meter

Data type: UNSIGNED_32

Index: 24396

d

= 5F4C

h

Display range

(min. value | unit | max. value)

0

s

4294967295

Read access  Write access  CINH  PLC STOP  No transfer