4 error id, 5 example for the bit coding of the error number, Error id – Lenze E94ARNE Regenerative power supply User Manual

Page 201: Example for the bit coding of the error number

Advertising
background image

EDS94ARNExxxx EN 2.3 - 06/2014

L

201

9400 regenerative power supply module | Parameter setting

Diagnostics & fault analysis

Error messages

8.6.1.4

Error ID

16-bit value (0 ... 65535

dec

) for error identification.

8.6.1.5

Example for the bit coding of the error number

C00168

displays the error number "1148911631".

This decimal value corresponds to the following bit sequence:

Error number "1148911631" thus means:

The "DC-bus undervoltage" error with the response "Trouble" has occurred in the

"Control" module with the instance ID 1.

0x00ad

173

CAN module in MXI2: CAN-NMT handler

0x00ae

174

CAN module in MXI2: CAN emergency handler

0x00af

175

CAN module in MXI2: CAN-NMT master

0x00b0

176

CAN module in MXI2: CAN-PDO handler

0x00b1

177

CAN module in MXI2: CAN-SDO server

0x00b2

178

CAN module in MXI2: CAN-SDO client

0x00c8

200

Intelligent communication module

Module ID

Module

hex

decimal

Bit 31

16

25

26

28

29

0

15

Assignment

Information

Meaning in the example

Response

2: Trouble

Instance ID

1: Instance ID 1

Module ID

Module ID 0x007b: control

Error ID

Error ID 0x000f for control:

DC-bus undervoltage

Bit 31

16

25

26

28

29

0

15

0 1 0 0 0 1 0 0 0 1 1 1 1 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1

0 1 0

0 0 1

0 0 0 1 1 1 1 0 1 1

0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1