I-1200 – Lenze E94ARNE Regenerative power supply User Manual

Page 156

Advertising
background image

9400 regenerative power supply module | Parameter setting

"CAN on board" system bus

Implemented CANopen objects

156

L

EDS94ARNExxxx EN 2.3 - 06/2014

I-1200

Identifier for the SDO server channel 1 (basic SDO channel).

According to DS301 V4.02, the basic SDO channel cannot be changed or deactivated.

[6-9]

Assignment of the data telegram

Index:

I-1200

Name:

SDO1 server parameter

Subindex

Default setting

Display range (min. value | unit | max. value)

Access

Data type

0: Highest subindex supported

2

2

2 ro

U8

1: COB-ID client -> server (rx)

Node ID + 0x600

0

4294967295 ro

U32

2: COB-ID server -> client (tx)

Node ID + 0x580

0

4294967295 ro

U32

Subindex

Meaning

1

Specification of the receive identifier

• For SDO server channel 1: node address (C00350) + 0x600

2

Specification of the transmit identifier

• For SDO server channel 1: node address (C00350) + 0x580

8th byte

7th byte

6th byte

5th byte

Data 4

Data 3

Data 2

Data 1

Bit 31

Bit 30

Bit 29 ... bit 11

Bit 10 ... bit 0

0

0

Extended identifier*

11-bit identifier

* The extended identifier is not supported - bits 11 ... 29 must be set to "0".