9400 regenerative power supply module | Parameter setting

"CAN on board" system bus

Process data transfer

6.6.2

Transmission type

Process data objects can be transmitted in an event-controlled or time-controlled manner.

Event-controlled: The PDO is sent when a special device-internal event has occurred,

for instance when the data contents of the TPDO have changed or when a transmission

cycle time has elapsed.

Synchronous: A TPDO (or RPDO) is transmitted (or received) after the device has

received a sync telegram (with the identifier 0x80).

Cyclic: The transmission of PDOs takes place at fixed time intervals after the

transmission cycle time has elapsed.

The following table shows that combinations of the different transmission methods by

means of logic operations (AND, OR) are also possible:

The communication parameters of each PDO (e.g. transmission mode and cycle time) can

be set freely and independently of the settings of other PDOs:

Tip!
The setting can also be made via the following CANopen objects:

I-1400

...

I-1403

: communication parameters for RPDO1 ... RPDO4

I-1800

...

I-1803

: communication parameters for TPDO1 ... TPDO4

Transmission type

PDO transmission

Logic operation

Cyclic

Synchronous

Event-controlled

0

AND

1 ... 240

-

254, 255

OR

Transmission type

Description

0

The PDO is transmitted on an event-controlled basis with every sync (e.g. when a bit change

occurs in the PDO).

1 ... 240

Sync (with response)

• Selection n = 1: The PDO is transmitted with every sync.

• Selection 1 < n ≤ 240: The PDO is transmitted with every nth sync.

254, 255

Event-controlled (with mask) with cyclic overlay

If this value is entered, the PDO is transmitted in an event-controlled or cyclic manner.

(Note: Currently the values "254" and "255" have the same meaning.)

Cyclic overlay is given if a cycle time is set for the respective PDO. In this case, cyclic

transmission takes place in addition to event-controlled transmission (e.g. when a bit

change occurs in the PDO).

Parameter

Information

Lenze setting

Value Unit

C00322/1...4

CAN TPDOx Tx mode

254

C00323/1...4

CAN RPDOx Rx mode

254

C00324/1...4

CAN TPDOx delay time

0 1/10 ms

C00356/1...4

CAN TPDOx cycle time

0 ms