C00133

C00134

C00137

C00138

C00142

Parameter | Name:

C00133 | Ref.: Brake chopper utilisation

Data type: UNSIGNED_8

Index: 24442

d

= 5F7A

h

Parameterising the brake chopper/brake resistor

Selection list

(Lenze setting printed in bold)

Information

0 Minimum resistance (C00134)

C00134

1 Resistance in C00129

C00129

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00134 | Minimum brake resistance

Data type: INTEGER_32

Index: 24441

d

= 5F79

h

Parameterising the brake chopper/brake resistor

Display range

(min. value | unit | max. value)

0.0

Ohm

500.0

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00137 | Brake transistor utilisation

Data type: INTEGER_32

Index: 24438

d

= 5F76

h

Parameterising the brake chopper/brake resistor

Display range

(min. value | unit | max. value)

0

%

250

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00138 | Brake resistor utilisation

Data type: INTEGER_32

Index: 24437

d

= 5F75

h

Parameterising the brake chopper/brake resistor

Display range

(min. value | unit | max. value)

0

%

250

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00142 | Autom. restart after mains ON

Data type: UNSIGNED_32

Index: 24433

d

= 5F71

h

Starting performance of the device after power-on or after resetting a "trouble" or "fault".

Automatic restart after mains power-on

Selection list

(Lenze setting printed in bold)

0 Inhibited
1 Enabled

Read access  Write access  CINH  PLC STOP  No transfer