C00150 | status word device control 1, C00155 | status word device control 2, C00150 – Lenze E94ARNE Regenerative power supply User Manual

Page 284: Status word

Advertising
background image

9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C00150

284

L

EDS94ARNExxxx EN 2.3 - 06/2014

C00150

C00155

Parameter | Name:

C00150 | Status word device control 1

Data type: BITFIELD_16

Index: 24425

d

= 5F69

h

Status word 1 of the

device interface

Value is bit-coded:

Information

Bit 0 Reserved

For the meaning of bits 8 ... 11 see chapter "

Device

states

".

Bit 1 Pulse inhibit active
Bit 2 Reserved
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Controller inhibit active
Bit 8 Device state - Bit 1
Bit 9 Device state - Bit 2

Bit 10 Device state - Bit 3
Bit 11 Device state - Bit 4
Bit 12 Warning active
Bit 13 Trouble active
Bit 14 Reserved
Bit 15 Reserved

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00155 | Status word device control 2

Data type: BITFIELD_16

Index: 24420

d

= 5F64

h

Status word 2 of the

device interface

Value is bit-coded:

Bit 0 Error status active
Bit 1 Reserved
Bit 2 Current limit reached
Bit 3 Reserved
Bit 4 Drive switched on/in operation
Bit 5 Drive ready for operation
Bit 6 Error active
Bit 7 Drive initialisation
Bit 8 Line rotates CCW
Bit 9 Reserved

Bit 10 Power regeneration blocked
Bit 11 Application active
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved