9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C00464

312

L

EDS94ARNExxxx EN 2.3 - 06/2014

C00464

C00465

C00466

C00467

C00468

C00469

C00512

Parameter | Name:

C00464 | Keypad: Mode

Data type: UNSIGNED_16

Index: 24111

d

= 5E2F

h

From software version V2.0 onwards

Definition of the mode for accessing the attached keypad.

• If both keypad versions (V1.0 and V2.0) are used, the Lenze setting has to be selected.

• If only the new keypad (V2.0) is used, the initialisation time of the keypad can be reduced by changing to mode

2. Furthermore, mode 2 will support larger keypad files in future.

Note: If mode 2 is selected, the V1.0 keypad cannot be operated on the controller!
Selection list

(Lenze setting printed in bold)

Information

0 Mode 1

For keypad V1.0 and V2.0

1 Mode 2

For keypad V2.0 only

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00465 | Keypad: Welcome screen time-out

Data type: UNSIGNED_8

Index: 24110

d

= 5E2E

h

Selection list

(Lenze setting printed in bold)

0 Never show welcome screen
5 5 min

15 15 min
30 30 min
60 60 min

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00466 | Keypad: Default parameters

Data type: UNSIGNED_16

Index: 24109

d

= 5E2D

h

Setting range

(min. value | unit | max. value)

Lenze setting

0

65535 0

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00467 | Keypad: Default welcome screen

Data type: UNSIGNED_8

Index: 24108

d

= 5E2C

h

Selection list

(Lenze setting printed in bold)

0 Main menu
1 Parameter list

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00468 | Service code

Data type: UNSIGNED_8

Index: 24107

d

= 5E2B

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C00469 | Service code

Data type: UNSIGNED_8

Index: 24106

d

= 5E2A

h

This code is used internally by the device and must not be overwritten by the user!

Parameter | Name:

C00512 | Service code

Data type: UNSIGNED_32

Index: 24063

d

= 5DFF

h

This code is used internally by the device and must not be overwritten by the user!