Wire the input power (ipd) connector – Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual

Page 106

Advertising
background image

106

Rockwell Automation Publication 2094-UM002E-EN-P - May 2012

Chapter 5

Connecting the Kinetix 6200 and Kinetix 6500 Drive System

Wire the Input Power (IPD) Connector

This example applies to any IAM module or common-bus leader IAM power
module.

Figure 55 - IAM Power Module (IPD connector)

Table 53 - Input Power (IPD) Connections

Table 54 - Termination Specifications

ATTENTION: Make sure the input power connections are correct when wiring
the IPD connector plug and that the plug is fully engaged in the module
connector. Incorrect wiring/polarity or loose wiring can cause explosion or
damage to equipment.

DC-

DC+

L3

L2

L1

1 2 3 4 5 6

Bulletin 2094
IAM Power Module, Top View

OPL Connector (LIM module

(1)

) or Other Three-phase Input

(1) The Bulletin 2094 power modules are compatible with only the 2094-BL02, 2094-BLxxS, and 2094-XL75-Cx LIM modules.

IPD Connector

(IAM or leader IAM module)

2094-AL09

LIM Module

2094-ALxxS, 2094-BLxxS, or

2094-XL75S-Cx LIM Modules

OPL Pin

Signal

OPL Pin

Signal

IPD Pin

Signal

1

L1’

4

L1’

6

L1

2

L2’

3

L2’

5

L2

3

L3’

2

L3’

4

L3

4

1

3

N/A

2

DC+

1

DC-

IAM Module Cat. No.

Input VAC

Recommended
Wire Size
mm

2

(AWG)

Strip Length
mm (in.)

Torque Value
N•m (lb•in)

2094-BC01-Mxx-M
2094-BC02-M02-M

460V AC

2.5 (14)

10 (0.38)

1.2…1.5
(10.6…13.2)

2094-BC04-M03-M

6 (10)

16 (0.63)

2.4…3.0
(21.6…26.5)

2094-BC07-M05-M

30 (3)

Advertising