Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual

Page 112

Advertising
background image

112

Rockwell Automation Publication 2094-UM002E-EN-P - May 2012

Chapter 5

Connecting the Kinetix 6200 and Kinetix 6500 Drive System

These cables contain only the three-phase power wires. The motors/actuators
either have no brake or a separate connector for brake connections. Thermal
switch wires are included in the feedback cable.

Refer to Axis Module/Rotary Motor Wiring Examples beginning on

page 242

for interconnect diagrams.

Figure 60 - Motor Power Terminations (cables without brake wires)

The cable shield clamp shown above is mounted to an IAM module. Cables
attach to the clamp on each AM module in the same way.

1 2

DC-

DC+

L3

L2

L1

CONT EN-

CONT EN+

CTRL 2

CTRL 1

1 2

1 2 3 4 5 6

W

V

U

MBRK -

MBRK +

COM

PWR

DBRK -

DBRK +

1 2 3 4

1 2 3 4 5 6

Motor Cable

Shield Clamp

Motor Power (MP) Connector Plug

Bulletin 2094
IAM/AM Power Module
(IAM module is shown)

Advertising