Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual

Page 206

Advertising
background image

206

Rockwell Automation Publication 2094-UM002E-EN-P - May 2012

Chapter 8

Troubleshooting the Kinetix 6200 and Kinetix 6500 Drive System

INIT FLT M12…INVALID KCL REV

Invalid KCL revision

The FPGA image is incompatible with hardware operation.

Flash control module with

correct firmware.

Replace module.

INIT FLT M13…INVALID BSP REV

Invalid BSP revision

The board support package is incompatible with hardware operation.

Flash control module with

correct firmware.

Replace module.

INIT FLT M14…SAFETY FIRMWARE

Invalid Safety Firmware

The loaded Safety firmware is not a valid revision for the rev of drive
firmware.

Flash control module with correct
revision of safety firmware.

INIT FLT M19…VOLTAGE MISMATCH

Voltage Mismatch on Power
Rail

The IAM detected that both 230V and 460V modules have been
installed on the same power rail.

Replace the mismatched AM
module with one that matches
the IAM module.

INIT FLT M20…UNKNOWN MODULE

Unknown Axis on Backplane

Unknown module is detected on the
modular backplane.

Faulty Module.

Recycle control power.
Replace module.

INIT FLT M21…FACTORY CFG

Factory Configuration

Factory Configuration Data is missing
or invalid.

Defective memory in
module.

Replace defective module.

INIT FLT M22…ILLEGAL ADDRESS

Illegal Node Switch Setting

AM Node Address is out of range
(>254).

IAM node switch set such
that an AM node address is
greater than 254.

Select IAM node address that
permits all AM node addresses to
be less than 254.

INIT FLT M23…SERIES MISMATCH

Series Mismatch on Power Rail

Sercos and EtherNet/IP control modules exist on the same power rail.

Replace the mismatched control
module.

INIT FLT M24…OPEN SLOT

Open Power Rail Slot

IAM detects an open slot on the power
rail.

Missing module or bent pins
on module.

Check control pin on back of

module.

Install slot filler module in

open slot.

INIT FLT M32…MTR KEYING nn
(Kinetix 6200 drives only)

Motor Keying Fault

The attached motor model does not
match the model in the axis
configuration. The nn sub-code is
defined as follows:
01: Encoder communication expected

but not operational.

02: Feedback type does not match.

03: Motor ID does not match.

04: Single-turn resolution does not

match.

Incorrect motor selected
from motor database.

Verify motor selection in Axis
Properties configuration.

INIT FLT M33…ENABLE
UNASSIGNED
(Kinetix 6200 drives only)

Enable Input Not Assigned

The enable function has been requested for use but has not been
assigned to a digital input.

Assign an available digital input
as Enable.

INIT FLT M34…OTRAVEL
UNASSIGNED
(Kinetix 6200 drives only)

Overtravel Input Not Assigned

The positive or negative overtravel function has been requested for use
but has not been assigned to a digital input.

Assign an available digital input
for the desired overtravel
function.

INIT FLT M35... NAND FLASH nn

Storage failure

The nn sub-code is defined as follows:
01: Main application storage failed.

02: Log file storage failed.

03: Web file storage failed.

Faulty memory component.

Recycle control power or reset

the drive.

Replace control module if

problem persists.

Table 83 - INIT FLT Fault Codes (continued)

Four-character
Display Message

RSLogix 5000
Fault Message

Problem or Symptom

Potential Cause

Possible Resolution

Advertising