Iam module, Without lim module) on, Figure 96 - iam module (without lim module) – Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual

Page 236: 2094-bc xx -m xx -m iam power module

Advertising
background image

236

Rockwell Automation Publication 2094-UM002E-EN-P - May 2012

Appendix A

Interconnect Diagrams

This configuration does not include a LIM module. You must supply input
power components. The single-phase and three-phase line filters are wired
downstream of fusing and the M1 contactor.

Figure 96 - IAM Module (without LIM module)

ATTENTION: Wiring the contactor enable (CED) relay is required. To avoid injury
or damage to the drive, wire the contactor enable relay into your safety control
string.

Refer to Contactor Enable Relay on

page 74

for more information.

DC-

DC+

L3

L2

L1

CTRL 2

CTRL 1

1

2

3

4

5

6

1

2

CONT EN-

CONT EN+

1

2

BR+

BR-

MBRK -

MBRK +

COM

PWR

DBRK -

DBRK +

W

V

U

BR+

BR-

4

3

2

1

6

5

4

3

2

1

Single-phase Input
95…264V AC RMS

Notes 1, 2

Isolation

Transformer *

Note 5

Three-phase Input

324…528V AC RMS

Notes 1, 2

Bonded Cabinet Ground Bus *

Control Power
(CPD) Connector

Power Rail
Ground Stud

DC Bus
and
Three-phase
Input (IPD)
Connector

Three-phase

AC Line Filter

Note 3

Input Fusing *

Input Fusing *

M1 *

Notes 8, 9

* Indicates User Supplied Component

2094-BCxx-Mxx-M

IAM Power Module

Chassis

Single-phase
AC Line Filter

Note 3

Note 4

STOP *

START *

CR1 *

CR1 *

CR1 *

M1 *

Contactor Enable
(CED) Connector
Note 14

Ground Jumper

Note 11

Refer to Attention statement (Note 13).

Notes 8, 14

24V AC/DC

or

120V AC

50/60 Hz

Motor Brake
Connections

Resistive Brake
Connections

User Supplied
24V DC

Motor/Resistive

Brake (BC) Connector

Three-phase
Motor Power
Connections
Note 16

Motor Power

(MP) Connector

Cable Shield

Clamp

Note 10

Refer to table on

page 232

for note information.

Advertising