Before you begin, Using the 2094 mounting brackets, Chapter 3 – Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual

Page 55: Chapter

Advertising
background image

Rockwell Automation Publication 2094-UM002E-EN-P - May 2012

55

Chapter

3

Mounting the Kinetix 6200 and Kinetix 6500
Drive System

This chapter provides the system installation procedures for mounting your
Kinetix 6200 and Kinetix 6500 drive components on the Bulletin 2094 power
rail.

This procedure assumes you have prepared your panel, mounted your Bulletin
2094 power rail, and understand how to bond your system. For installation
instructions regarding equipment and accessories not included here, refer to the
instructions that came with those products.

Before You Begin

Before you begin, consider your Bulletin 2094 power rail installation and using
2094 mounting brackets.

Using the 2094 Mounting Brackets

You can use Bulletin 2094 mounting brackets to mount the power rail or LIM
module over the AC line filter. Refer to the 2094 Mounting Brackets Installation
Instructions, publication

2094-IN008

, when using mounting brackets with your

Kinetix 6200 and Kinetix 6500 drive system.

Topic

Page

Before You Begin

55

Determine Mounting Order

56

Mount Modules on the Power Rail

57

Mount the Control Modules

60

SHOCK HAZARD: To avoid hazard of electrical shock, perform all mounting and
wiring of the Bulletin 2094 power rail and drive modules prior to applying
power. Once power is applied, connector terminals may have voltage present
even when not in use.

ATTENTION: Plan the installation of your system so that you can perform all
cutting, drilling, tapping, and welding with the system removed from the
enclosure. Because the system is of the open type construction, be careful to
keep any metal debris from falling into it. Metal debris or other foreign matter
can become lodged in the circuitry, which can result in damage to components.

Advertising