Wiring the feedback and i/o connectors, Connect premolded motor feedback cables – Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual

Page 123

Advertising
background image

Rockwell Automation Publication 2094-UM002E-EN-P - May 2012

123

Connecting the Kinetix 6200 and Kinetix 6500 Drive System

Chapter 5

Wiring the Feedback and I/O
Connectors

These procedures assume you have mounted your Kinetix 6200 and
Kinetix 6500 system, completed all power wiring, and are ready to connect your
feedback and I/O cables.

Connect Premolded Motor Feedback Cables

Motor feedback cables with premolded connectors plug directly into 15-pin
motor feedback (MF) connectors on the control modules (no wiring is
necessary).

Figure 65 - IAM/AM Power Module/Control Module (MF connector)

For This Connection

Go to

Premolded cable

Connect Premolded Motor Feedback Cables on

page 123

.

Panel-mounted breakout board

Connect Panel-mounted Breakout Board Kits on

page 124

.

Low-profile connector

Wire Low-profile Connector Kits on

page 125

.

IMPORTANT

When using Bulletin 2090 cables with premolded connectors, tighten the
mounting screws (finger tight) to improve system performance.

Kinetix 6200 or Kinetix 6500, Front View

(IAM power module with

control module is shown)

Kinetix 6200 or Kinetix 6500, Side View
(IAM power module with
control module is shown)

Premolded Connector
(2090-UXNFBMP-Sxx Cable

Motor Feedback (MF) Connector