Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual

Page 94

Advertising
background image

94

Rockwell Automation Publication 2094-UM002E-EN-P - May 2012

Chapter 5

Connecting the Kinetix 6200 and Kinetix 6500 Drive System

Figure 48 - Grounded (B-Phase) Power Configuration (Delta Secondary)

The IAM power module has a factory-installed ground jumper configured for
grounded power distribution.

Refer to Appendix A on

page 233

, for input-power interconnect diagrams with

and without the LIM module.

L3

L1

L2

1 2

DC-

DC+

L3

L2

L1

CONT EN-

CONT EN+

CTRL 2

CTRL 1

1 2

1 2 3 4 5 6

W

V
U

MBRK -

MBRK +

COM

PWR

DBRK -

DBRK +

1 2 3 4

1 2 3 4 5 6

Transformer (Delta) Secondary

Bonded Cabinet

Ground

Transformer

Ground Grid or

Power Distribution Ground

Connect to power rail ground stud.

Three-phase

AC Line Filter

Input Fusing

M1

Contactor

Bulletin 2094

IAM Power Module, Top View

IMPORTANT

If you determine that you have grounded power distribution in your plant, you
do not need to modify your IAM power module.