Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual

Page 67

Advertising
background image

Rockwell Automation Publication 2094-UM002E-EN-P - May 2012

67

Kinetix 6200 and Kinetix 6500 Connector Data

Chapter 4

I/O, Safety, and Auxiliary Feedback Connector Pinout

Refer to the Kinetix 6200 and Kinetix 6500 Safe Speed Monitoring Safety
Reference Manual, publication

2094-RM001

, for more information on safe-

speed monitoring safety functions.

Refer to the Kinetix 6200 and Kinetix 6500 Safe Torque-off Safety Reference
Manual, publication

2094-RM002

, for more information on safe torque-off

safety functions.

IOD Pin

(1)

Description

Signal

IOD Pin

(1)

Description

Signal

1

Sine differential input +
A differential input +

AUX_SIN+
AUX_A+

23

(S52)

Safe limited speed input 0

SLS_IN_CH0

Safe stop input 2

SS_IN_CH2

(2)

2

Sine differential input -
A differential input -

AUX_SIN-
AUX_A-

24

(S62)

Safe limited speed input 1

SLS_IN_CH1

Safe stop input 3

SS_IN_CH3

(2)

3

Cosine differential input +
B differential input +

AUX_COS+
AUX_B+

25

Reset reference

RESET_REF

4

Cosine differential input -
B differential input -

AUX_COS-
AUX_B-

26 (S34)

Reset

input

RESET_IN

5

Data differential input +
Index differential input +

AUX_DATA+
AUX_I+

27

(S11)

Pulse test output 0

TEST_OUT_0

6

Data differential input -
Index differential input -

AUX_DATA-
AUX_I-

28

(S21)

Pulse test output 1

TEST_OUT_1

7

Clock output +

AUX_CLK+

29

(68)

Safe limited speed output 0

SLS_OUT_CH0

8

Clock output -

AUX_CLK-

30

(78)

Safe limited speed output 1

SLS_OUT_CH1

9

Encoder 5V power output

EPWR5V

31

(S32)

Door monitor input 0

DM_IN_CH0

10

Encoder common

ECOM

32

(S42)

Door monitor input 1

DM_IN_CH1

11

Encoder 9V power output

EPWR9V

33

(X32)

Lock monitor input 0

LM_IN_CH0

12

Reserved

34

(X42)

Lock monitor input 1

LM_IN_CH1

13

Reserved

35

(51)

Door control channel output-

DC_OUT_CH0

14

24V power out

24VPWR

(2)

36

(52)

Door control channel output+

DC_OUT_CH1

15

24V common

24VCOM

(2)

37

(S72)

Enabling switch monitor input 0

ESM_IN_CH0

16

Reserved

38

(S82)

Enabling switch monitor input 1

ESM_IN_CH1

17

(A1)

Safety 24V power input

SPWR

39

24V power out

24VPWR

(3)

18

(A2)

Safety 24V common

SCOM

40

24V common

24VCOM

(3)

19

(S12)

Safe stop input 0

SS_IN_CH0

41

Digital input 1 (drive enable)

INPUT1

(4)

20

(S22)

Safe stop input 1

SS_IN_CH1

42

Digital input 2 (home)

INPUT2

(4)

21

(34)

Safe stop output 0

SS_OUT_CH0

43

Digital input 3 (registration 1)

INPUT3

(4)

22

(44)

Safe stop output 1

SS_OUT_CH1

44

Digital input 4 (registration 2)

INPUT4

(4)

(1) Designators in parenthesis refer to the Guardmaster® MSR57P safety relay and PowerFlex 750-Series safety option terminals.
(2) This signal applies to only the 2094-SE02F-M00-S0 and 2094-EN02D-M01-S0 control modules. Use this supply to power the Safety 24V (SPWR/SCOM) input. Do not connect this 24V supply

to any external safety device.

(3) Use signals 24VPWR and 24VCOM (IOD-39 and IOD-40) as a 24V DC source to operate the digital inputs (50 mA maximum per input).
(4) Default assignments are in parenthesis. Use sercos IDN Write instruction to change default assignments. Refer to

Digital Inputs

on

page 71

for more information.

Advertising