Rockwell Automation Publication 2094-UM002E-EN-P - May 2012

57

Mounting the Kinetix 6200 and Kinetix 6500 Drive System

Chapter 3

Figure 25 - Module Mounting Order Example

Mount Modules on the Power
Rail

Follow these steps to mount the IAM, AM, IPIM, shunt, and slot-filler modules.

1. Remove the protective covers from the power rail connectors.

Highest Power Utilization

Lowest Power Utilization

Integrated Axis Module

2094-BC02-M02-M

IPIM Module

2094-SEPM-B24-S

Axis Module

2094-BM01-M

Axis Module

2094-BM01-M

Axis Module

2094-BMP5-M

Axis Module

2094-BMP5-M

Shunt Module

2094-BSP2

Slot-filler Module

2094-PRF

IMPORTANT

The IAM module must be positioned in the leftmost slot of the power rail.
Position your AM/IPIM modules, shunt module, and slot-filler modules to the
right of the IAM module.

The shunt module must be installed to the right of the last AM/IPIM module.
Only slot-filler modules may be installed to the right of the shunt module.

Do not mount the shunt module on power rails with a follower IAM module.
Common-bus follower IAM modules will disable the internal, rail mounted,
and external shunt modules.

SHOCK HAZARD: To avoid personal injury due to electrical shock, place a 2094-
PRF slot-filler module in all empty slots on the power rail. Any power rail
connector without a module installed will disable the Bulletin 2094 system;
however, control power will still be present.

TIP

All modules mount to the power rail by using the same technique; however,
only the IAM module is used in the examples.

IMPORTANT

The IAM module must be positioned in the leftmost slot of the power
rail. Position your axis modules, shunt module, and slot-filler modules
to the right of the IAM module.