142

Rockwell Automation Publication 2094-UM002E-EN-P - May 2012

Chapter 6

Configure and Start the Kinetix 6200 Drive System

Figure 85 - Node Addressing Example 1

In Example 1, the Kinetix 6200 (6-axis) drive system 1 power rail contains four
control modules, one shunt module, and one slot-filler module. The shunt
module and slot-filler modules are not assigned a sercos node address, but the
system identifies them with a slot location.

Kinetix 6200 (2-axis) drive system 2 power rail contains two control modules.
The base node address of the (system 2) control module must be set for an
address of

≥007.

SERCOS interface

TM

Tx (rear)

Rx (front)

OK

CP

6200

6200

SAFE SPEED

6200

6200

SAFE SPEED

6200

6200

SAFE SPEED

6200

6200

SAFE SPEED

6200

6200

SAFE SPEED

6200

6200

SAFE SPEED

0 0 1

Kinetix 6200 Drive
System 2
(2-axis power rail)

006 = Slot-filler module slot location
005 = Shunt module slot location
004 = Control module (AM axis 4) node address
003 = Control module (AM axis 3) node address
002 = Control module (AM axis 2) node address
001 = Control module (IAM axis 1) base node address

Logix Platform
(ControlLogix is shown)

Sercos Fiber-optic Ring

1756-MxxSE Sercos
interface Module

008 = Control module (AM axis 2) node address
007 = Control module (IAM axis 1) base node address

Kinetix 6200 Drive

System 1 (6-axis power rail)

Receive

Receive

Transmit

Transmit

Transmit

Receive

Base Node Address

Switches

IMPORTANT

The node address for each AM (control) module is determined by the base
node-address switch setting on the IAM power module.

Do not position axis modules to the right of shunt or slot-filler modules. The
added distance between non-adjacent axes can increase electrical noise and
impedance, and requires longer fiber-optic cable lengths.

IMPORTANT

Slot-filler modules must be used to fill any unoccupied slot on the power rail.
However, you can replace slot-filler modules with AM power modules or the
2094-BSP2 shunt module (maximum one 2094-BSP2 shunt module per power
rail).