Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual

Page 220

Advertising
background image

220

Rockwell Automation Publication 2094-UM002E-EN-P - May 2012

Chapter 8

Troubleshooting the Kinetix 6200 and Kinetix 6500 Drive System

FLT M28…SAFETY COMM

Internal Safety
Communication

Communication with the safety hardware within the drive
malfunctioned.

Coast/Disable (open
contactor enable relay)

Coast/Disable (open
contactor enable relay)

FLT M64…SENSOR ASSIGNMENT

Sensor Assignment

The Home, Registration1, or Registration 2 digital input
function has been requested but is not assigned to an input.
Multiple inputs have been assigned the same function.

Coast/Disable

Coast/Disable

FLT M68…IPIM

IPIM Module Fault

A fault has occurred in one or more IPIM modules on the power
rail.

N/A

Coast/Disable (open
contactor enable relay)
Applies to the IAM
module.

Table 102 - Drive Behavior, FLT Mxx Fault Codes (continued)

Four-character Display Message

RSLogix 5000 Fault
Message

Description

CIP Motion
Exception Behavior

Sercos Fault
Behavior

Table 103 - Drive Behavior, NODE FLT Fault Codes

Four-character Display Message

RSLogix 5000 Fault
Message

Description

CIP Motion and Sercos
Drive Behavior

NODE FLT 01…LATE CTRL UPDATE
(Kinetix 6500 drives only)

Control Update Fault

Several consecutive updates from the controller have been lost.

Decel/Disable

NODE FLT 02…PROC WATCHDOG

Processor Watchdog
Fault

The watchdog circuit monitoring processor operation detected a problem.

Coast/Disable

NODE FLT 03…HARDWARE nn

Hardware Fault

The drive has an internal hardware problem. The nn sub-code is defined as
follows:
01: Invalid slot ID.

02: Cannot read slot ID.

03: Nonvolatile write to memory failed.

04: Nonvolatile memory read failed.

Coast/Disable (open
contactor enable relay)

NODE FLT 04…DATA FORMAT ERROR
(Kinetix 6200 drives only)

Data Format Error

A data format error was discovered in the controller-to-drive message.

Coast/Disable

NODE FLT 06…LOST CTRL CONN
(Kinetix 6500 drives only)

Lost Controller
Connection

communication with the controller have been lost

Decel/Disable

NODE FLT 08…LOGIC WATCHDOG
(Kinetix 6500 drives only)

Custom Logic Update
Timeout

The watchdog circuit monitoring custom logic operation detected a problem.

Coast/Disable (open
contactor enable relay)

NODE FLT 09…IP ADDRESS
(Kinetix 6500 drives only)

Duplicate IP Address

This drive and another EtherNet device on the same subnet have identical IP
addresses.

Coast/Disable

NODE FLT 128…DRAM TEST

DRAM Test Fault

A power-up test of the DRAM indicated a memory problem.

Coast/Disable (open
contactor enable relay)

NODE FLT 129…FPGA CONFIG

FPGA Configuration
Fault

The FPGA could not be configured properly.

Coast/Disable (open
contactor enable relay)

NODE FLT 133…SERCOS ADDRESS
(Kinetix 6200 drives only)

Duplicate Sercos Node
Address

This axis and one or more other axes have identical sercos addresses.

Coast/Disable

NODE FLT 139…SERCOS RING
(Kinetix 6200 drives only)

Sercos Ring Fault

The sercos ring is not active after being active and operational.

Decel/Disable

Advertising