Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual

Page 20

Advertising
background image

20

Rockwell Automation Publication 2094-UM002E-EN-P - May 2012

Chapter 1

Start

The Kinetix 6500 control modules can use any Ethernet topology including star,
linear, and device-level ring (DLR). DLR is an ODVA standard and provides
fault tolerant connectivity.

In this example, all devices are connected in linear topology. The Kinetix 6500
control module includes dual-port connectivity. Devices without dual ports
should include the 1783-ETAP module or be connected at the end of the line.

Up to 64 devices in linear configurations.
No redundancy. If any device becomes disconnected, all the devices

downstream loose communication.

Figure 6 - Kinetix 6500 Linear Communication Installation (EtherNet/IP network)

TIP

1756-EN2F modules are available for applications that require fiber-optic cable
for noise immunity.

Logix Platform
(ControlLogix

is shown)

RSLogix 5000

Software

Kinetix 6500 Modular Multi-axis Servo Drive System

1585J-M8CBJM-x

Ethernet (shielded) Cable

1756-ENxT EtherNet/IP Module

1734-AENT POINT I/O™

EtherNet/IP Adapter

ControlLogix Controller Programming Network

PanelView™ Plus

Display Terminal

1783-ETAP

Modules

PowerFlex® 755

Drive Modules

2094-BMxx-M Axis Modules (5) with

2094-EN02D-M01-Sx Control Modules (5)

2094-BCxx-Mxx-M

Integrated

Axis Module

with

2094-EN02D-M01-Sx

Control Module

1585J-M8CBJM-OM3

0.3 m (1.0 ft) Ethernet cable

for drive-to-drive connections.

Advertising