Follow these steps to configure the IAM power module and the control modules
attached to your IAM and AM power modules.

1. Verify that no power is applied to the IAM and AM power modules and

that the communication cables are plugged into the appropriate
connectors.

To verify communication, refer to Sercos Fiber-optic Cable Connections
on

page 131

.

2. Set the base node address for the IAM power module by setting the Node

Address switches.

Valid node addresses for sercos communication are 001…099. The left
switch sets the most significant digit (MSD) and the right switch sets the
least significant digit (LSD).

Setting the base node address on the IAM power module determines the
node address for the control module mounted on the IAM (inverter)
module. Node addressing for all slot locations on the same power rail
increment (from the IAM inverter) left to right.

3. Cycle control power to initialize the IAM module.

IMPORTANT

If you have one or more IDM power interface modules (IPIM) on your power
rail, refer to the Kinetix 6000M Integrated Drive-Motor System User
Manual, publication

2094-UM003

, for system configuration information

specific to the Kinetix 6000M IDM system.

To Configure

Begin With

The IAM module

step 2

Any control module

step 4

Kinetix 6000M IDM system

(1)

(1) Sercos fiber-optic cable connections for the Kinetix 6000M integrated drive-motor (IDM) system are on

page 134

.

Kinetix 6000M Integrated Drive-Motor User Manual,
publication

2094-UM003

.

To

Press

Increment the (MSD/LSD) node address

The plus (+) switch.

Decrement the (MSD/LSD) node address

The minus (-) switch.

IMPORTANT

The base node address setting takes effect only after the IAM power
module is initialized.

Decrements MSD

MSD

Increments MSD

Decrements LSD

LSD

Increments LSD

Advertising