Chapter 6

Configure and Start the Kinetix 6200 Drive System

Figure 87 - Node Addressing Example 3

In this example, the Kinetix 6200 (8-axis) power rail contains a double-wide
IAM module, two double-wide AM modules, one single-wide AM module, and
one slot-filler module. The slot-filler module is not assigned a sercos node
address, but the system identifies it with a slot location.

The leftmost slot of a double-wide module determines the node address. So, in
the example above, node addresses 02, 04, and 06 (the rightmost slots of the
double-wide modules) are not used.

SERCOS interface

TM

Tx (rear)

Rx (front)

OK

CP

6200

6200

SAFE SPEED

6200

6200

SAFE SPEED

6200

6200

SAFE SPEED

6200

6200

SAFE SPEED

0 0 1

008 = Slot-filler module node address
007 = AM module (axis 4) node address
006 = Not Used (AM module rightmost slot)
005 = AM module (axis 3) node address
004 = Not Used (AM module rightmost slot)
003 = AM module (axis 2) node address
002 = Not Used (IAM module rightmost slot)
001 = IAM module (axis 1) base node address

Logix Platform
(ControlLogix controller is shown)

Sercos Fiber-optic Ring

1756-MxxSE Sercos
interface Module

Kinetix 6200 Drive System

(8-axis power rail)

Receive

Transmit

Transmit

Receive

Base Node Address

Switches

IMPORTANT

The node address for each AM (control) module is determined by the base
node-address switch setting on the IAM power module.

Do not position axis modules to the right of shunt or slot-filler modules. The
added distance between non-adjacent axes can increase electrical noise and
impedance, and requires longer fiber-optic cable lengths.

IMPORTANT

Slot-filler modules must be used to fill any unoccupied slot on the power rail.
However, you can replace slot-filler modules with AM power modules or the
2094-BSP2 shunt module (maximum one 2094-BSP2 shunt module per power
rail).