Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual

Page 59

Advertising
background image

Rockwell Automation Publication 2094-UM002E-EN-P - May 2012

59

Mounting the Kinetix 6200 and Kinetix 6500 Drive System

Chapter 3

5. Gently push the module against the power rail connectors and into the

final mounting position.

6. Use 2.26 N•m (20 lb•in) torque to tighten the mounting screws.

Repeat

step 1

through

step 6

for each AM, IPIM, shunt, or slot-filler module in

your Bulletin 2094 drive system

TIP

The IAM module can have two or three power rail connectors and guide pins,
the AM module can have one or two, all other modules have one.

Power Rail

Bracket secured in slot.

IAM or AM Power Module, IPIM,
Shunt, or Slot-filler Module
(IAM power module is shown)

Bottom front view of the

double-wide IAM or AM power module.

(AM power module is shown).

Mounting Screws

Bottom front view of the
single-wide AM, IPIM, shunt,
or slot-filler module
(AM power module is shown).

IMPORTANT

There are two mounting screws when mounting 2094-BC04-M03-M, and
2094-BC07-M05-M (double-wide) IAM modules, and 2094-BM03-M and
2094-BM05-M (double-wide) AM modules.

Advertising