Minimum Clearance Requirements

This section provides information to assist you in sizing your cabinet and
positioning your Bulletin 2094 system components.

Figure 10

illustrates minimum clearance requirements for proper airflow and

installation:

Additional clearance is required for the cables and wires connected to the

top and front of the drive.

Additional clearance left and right of the power rail is required when the

drive is mounted adjacent to noise sensitive equipment or clean wireways.

Figure 10 - Minimum Clearance Requirements

(1) The power rail (slim), catalog number 2094-PRSx, extends left and right of the first and last module 5.0 mm (0.20 in.). The Bulletin

2094-PRx power rail extends approximately 25.4 mm (1.0 in.) left of the IAM module and right of the last module mounted on the
rail.

Table 9 - Minimum Cabinet Depth

IMPORTANT

Mount the module in an upright position. Do not mount the module on its side.

F

Clearance right of the

module is not required.

(1)

Clearance above

for airflow and installation.

Clearance left of the

module is not required.

(1)

Kinetix 6200 or

Kinetix 6500 Drive System

Mounted on 2094 Power Rail

80 mm (3.10 in.) clearance below
drive for airflow and installation.

Drive Cat. No.

F

2094-BC01-Mxx-M
2094-BC02-M02-M

285 mm
(11.2) in.

2094-BMP5-M,
2094-BM01-M,
2094-BM02-M

2094-SEPM-B24-S
2094-BSP2

287 mm
(11.3) in.

2094-BC04-M03-M
2094-BM03-M

375 mm
(14.7) in.

2094-BC07-M05-M
2094-BM05-M

Refer to Power Dissipation Specifications on

page 34

, and

Kinetix Servo Drives Technical Data, publication

GMC-TD003

,

for Kinetix 6000 drive dimensions.

Drive Cat. No.

Cabinet Depth, min

(1)

Drive Cat. No.

Cabinet Depth, min

(1)

2094-BC01-Mxx-M, 2094-BC02-M02-M,
2094-BMP5-M, 2094-BM01-M, 2094-BM02-M

302 mm (11.9 in.)

2094-BC04-M03-M, 2094-BC07-M05-M,
2094-BM03-M, 2094-BM05-M

302 mm (11.9 in.)

2094-BSP2

272 mm (10.7 in.)

2094-SEPM-B24-S

263 mm (10.3 in.)

(1) Minimum cabinet depth is based on the use of 2090-K6CK-xxxx low-profile connector kits. Other means of making feedback connections may require additional clearance.