Chapter 7

Configure and Start the Kinetix 6500 Drive System

21. Calculate additional bus capacitance, if this applies to your application,

and enter the value here (version 18.00 or later), or refer to Appendix D on

page 271

to set the Add Bus Cap parameter.

The Additional Bus Capacitance field only applies to the IAM power
module.

22. Click OK.
23. Repeat

step 1

through

step 18

for each 2094-EN02D-M01-S

x control

module.

IMPORTANT

When configured to use the Bulletin 1394 or 2094 shunt modules, the
IAM bus regulator capacity attribute displays the utilization of total
shunt power available (as a percent) based on the power rail
configuration.

Refer to Kinetix Motion Accessories Specifications Technical Data,
publication

GMC-TD004

, for more information.

IMPORTANT

DC common-bus applications must calculate Total Bus Capacitance and
Additional Bus Capacitance and set the Add Bus Cap parameter in the
leader IAM power module. However, you can set the parameter as
shown in

step 21

or by using RSLogix 5000 software as shown in

Appendix D.

Refer to Appendix C beginning on

page 267

, for more information on

making the calculations. Refer to Appendix D beginning on

page 271

,

for more information on setting the Add Bus Cap parameter.