Chapter 2

Table 14 - Shunt Module

Table 15 - IDM Power Interface Module (IPIM)

Table 16 - Resistive Brake Module (RBM)

Wire/Cable

Connector

Zone

Method

Very
Dirty

Dirty

Clean

Ferrite
Sleeve

Shielded
Cable

COL, DC+ (shielded option)

RC

X

X

COL, DC+ (unshielded option)

X

Thermal switch

TS

X

X

Fan (if present)

N/A

X

Wire/Cable

Zone

Method

Very Dirty

Dirty

Clean

Ferrite Sleeve

Shielded Cable

Hybrid DC bus power, control power,
inter-module communication, and safe-off

(1)

X

X

Enable input

X

X

Fiber-optic

No restrictions

Ethernet network

X

X

IDM network

(1)

X

X

(1) There is no option for making your own hybrid power or IDM network cables.

Wire/Cable

Connections

Zone

Method

Very Dirty

Dirty

Clean

Ferrite Sleeve

Shielded Cable

Resistive brake module coil power

TB3-6 and TB3-7

X

Resistive brake module I/O

TB1-1…TB1-5
and TB3-8

X

Resistive brake module drive and motor power

TB1 and TB2

X

X

230V power

TB4

X

Advertising