Upgrade drive firmware with controlflash software, Before you begin – Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual

Page 258

Advertising
background image

258

Rockwell Automation Publication 2094-UM002E-EN-P - May 2012

Appendix B

Upgrading the Drive Firmware

Upgrade Drive Firmware
with ControlFLASH Software

Upgrading axis module firmware by using ControlFLASH software involves
configuring your Logix communication, selecting the drive to upgrade, and
upgrading the firmware.

Before You Begin

The firmware revision for software and modules varies, depending on whether
your drive system uses sercos or EtherNet/IP networks.

Table 109 - Kinetix 6200 (sercos interface) System Requirements

Table 110 - Kinetix 6500 (EtherNet/IP network) System Requirements

IMPORTANT

If the xx02x-Mxx-S0 (safe torque-off) drive firmware contains updated safety
firmware, you must de-energize the safety inputs first or the upgrade will fail.

Description

Cat. No.

Firmware Revision

RSLogix 5000

software

9324-RLD300NE

17.x or later

ControlLogix sercos module

1756-MxxSE

17.16 or later

1756-L60M03SE

17.2 or later

CompactLogix sercos module

1768-M04SE

17.16 or later

SoftLogix sercos PCI card

1784-PM16SE

17.10 or later

RSLinx® software

2.54 or later

ControlFLASH software kit

(1)

4.00.00 or later

Catalog numbers of the targeted Kinetix 6200 drive module you want to flash.

Network path to the targeted Kinetix 6200 drive module you want to flash.

Description

Cat. No.

Firmware Revision

RSLogix 5000

software

9324-RLD300NE

18.x or later

RSLinx software

2.54 or later

ControlFLASH software kit

(1)

(1) Download the ControlFLASH kit from

http://support.rockwellautomation.com/controlflash

. Contact Rockwell Automation Technical

Support at (440) 646-5800 for assistance.
For more ControlFLASH information (not drive specific), refer to the ControlFLASH Firmware Upgrade Kit User Manual, publication

1756-UM105

.

8.00.017 or later

Catalog numbers of the targeted Kinetix 6500 drive module you want to flash.

Network path to the targeted Kinetix 6500 drive module you want to flash.