Upgrade drive firmware with controlflash software, Before you begin – Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual
Page 258

258
Rockwell Automation Publication 2094-UM002E-EN-P - May 2012
Appendix B
Upgrading the Drive Firmware
Upgrade Drive Firmware
with ControlFLASH Software
Upgrading axis module firmware by using ControlFLASH software involves
configuring your Logix communication, selecting the drive to upgrade, and
upgrading the firmware.
Before You Begin
The firmware revision for software and modules varies, depending on whether
your drive system uses sercos or EtherNet/IP networks.
Table 109 - Kinetix 6200 (sercos interface) System Requirements
Table 110 - Kinetix 6500 (EtherNet/IP network) System Requirements
IMPORTANT
If the xx02x-Mxx-S0 (safe torque-off) drive firmware contains updated safety
firmware, you must de-energize the safety inputs first or the upgrade will fail.
Description
Cat. No.
Firmware Revision
RSLogix 5000
software
9324-RLD300NE
17.x or later
ControlLogix sercos module
1756-MxxSE
17.16 or later
1756-L60M03SE
17.2 or later
CompactLogix sercos module
1768-M04SE
17.16 or later
SoftLogix sercos PCI card
1784-PM16SE
17.10 or later
RSLinx® software
2.54 or later
ControlFLASH software kit
(1)
4.00.00 or later
Catalog numbers of the targeted Kinetix 6200 drive module you want to flash.
Network path to the targeted Kinetix 6200 drive module you want to flash.
Description
Cat. No.
Firmware Revision
RSLogix 5000
software
9324-RLD300NE
18.x or later
RSLinx software
2.54 or later
ControlFLASH software kit
(1)
(1) Download the ControlFLASH kit from
. Contact Rockwell Automation Technical
Support at (440) 646-5800 for assistance.
For more ControlFLASH information (not drive specific), refer to the ControlFLASH Firmware Upgrade Kit User Manual, publication
8.00.017 or later
Catalog numbers of the targeted Kinetix 6500 drive module you want to flash.
Network path to the targeted Kinetix 6500 drive module you want to flash.