Peak current specifications, D = t t, X 100 – Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual

Page 77

Advertising
background image

Rockwell Automation Publication 2094-UM002E-EN-P - May 2012

77

Kinetix 6200 and Kinetix 6500 Connector Data

Chapter 4

Peak Current Specifications

Figure 36 - Load Duty-cycle Profile Example

Table 31 - Peak Duty Cycle Definition of Terms

D = T

T

PK

x 100%

I

Cont

I

Base

I

PK

T

PK

T

Term

Definition

(1)

(1) All current values are specified as RMS.

Continuous Current Rating (I

Cont

)

The maximum value of current that can be output continuously.

Peak Current Rating (I

PKmax

)

The maximum value of peak current that the drive can output. This rating is
valid only for overload times less than T

PKmax

.

Duty Cycle (D)

The ratio of time at peak to the Application Period and is defined as:

Time at Peak (T

PK

)

The time at peak current (I

PK

) for a given loading profile. Must be less than or

equal to T

PKmax

.

Peak Current (I

PK

)

The level of peak current for a given loading profile. I

PK

must be less than or

equal to the Peak Current Rating (T

PKMAX

)

of the drive.

Base Current (I

Base

)

The level of current between the pulses of peak current for a given loading
profile. I

Base

must be less than or equal to the continuous current rating (I

Cont)

of the drive.

Loading Profile

The loading profile is comprised of I

PK

, I

Base

, T

PK

, and D (or T) values and

completely specify the operation of the drive in an overload situation. These
values are collectively defined as the Loading Profile of the drive.

Application Period (T)

The sum of the times at I

PK

(T

PK

) and I

Base

.

D = T

T

PK

x 100%

Advertising