Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual

Page 222

Advertising
background image

222

Rockwell Automation Publication 2094-UM002E-EN-P - May 2012

Chapter 8

Troubleshooting the Kinetix 6200 and Kinetix 6500 Drive System

SAFE FLT 13…MOTION AFTER STOP

Motion After Stopped
Fault

Motion has been detected after the axis was already detected as stopped and
the door was unlocked.

Coast-Disable

SAFE FLT 14…SLS IN

SLS Input Fault

The safe limited speed (SLS) input circuitry has detected a problem.

Coast-Disable

(1)

SAFE FLT 15…SLS OUT

SLS Output Fault

The safe limited speed (SLS) output circuitry has detected a problem.

Coast-Disable

(1)

SAFE FLT 16…SLS SPEED

SLS Speed Fault

The monitored speed has exceeded the safe limited speed (SLS) limit.

Coast-Disable

(1)

SAFE FLT 17…SMS SPEED

SMS Speed Fault

The monitored speed has exceeded the safe maximum speed (SMS) limit.

Coast-Disable

(1)

SAFE FLT 18…ACCELERATION

Acceleration Fault

The motor was detected not accelerating fast enough.

Coast-Disable

(1)

SAFE FLT 19…DIRECTION

Direction Fault

The monitored direction was found to be in the restricted direction.

Coast-Disable

(1)

SAFE FLT 20…DM IN

DM Input Fault

The door monitor (DM) input was detected as OFF when it should have been
ON.

Coast-Disable

(1)

SAFE FLT 21…DOOR MONITORING

Door Monitoring

The door monitor (DM) input was detected as being in the wrong state.

Coast-Disable

(1)

SAFE FLT 22…DC OUT

DC Output Fault

The door control (DC) output circuitry has detected a problem.

Coast-Disable

(1)

SAFE FLT 23…LM IN

LM Input Fault

The lock monitor (LM) input circuitry has detected a problem.

Coast-Disable

(1)

SAFE FLT 24…LOCK MONITORING

LM Input State Fault

The lock monitor (LM) input was detected as OFF when the Door should have
been locked or detected as ON when the door was opened.

Coast-Disable

(1)

SAFE FLT 25…ESM IN

ESM Input Fault

The enabling switch monitor (ESM) input was detected as OFF when it should
have been ON.

Coast-Disable

(1)

SAFE FLT 26…ESM MONITORING

ESM Input State Fault

The enabling switch monitor (ESM) input was detected as being in the wrong
state.

Coast-Disable

(1)

SAFE FLT 27…ENCODER 1 VOLTAGE

Encoder 1 Voltage
Fault

Encoder voltage is outside of the limits.

Coast-Disable

SAFE FLT 28…ENCODER 2 VOLTAGE

Encoder 2 Voltage
Fault

Encoder voltage is outside of the limits.

Coast-Disable

(1) The Safe Stop fault behavior is determined by parameter settings in the safety configuration.

Table 104 - Drive Behavior, SAFE FLT Fault Codes (continued)

Four-character Display Message

RSLogix 5000 Fault
Message

Description

CIP Motion and Sercos
Drive Behavior

Advertising