21

Start

Chapter 1

In this example, the devices are connected by using device-level ring (DLR)
topology. DLR topology is fault redundant. For example, if a device in the ring is
disconnected, the rest of the devices in the ring continue to maintain
communication.

Up to 64 devices in the DLR configurations.
All Devices in a DLR ring should have dual-port connectivity or be

connected in the ring by using a 1783-ETAP module.

Figure 7 - Kinetix 6500 Ring Communication Installation (EtherNet/IP network)

755

ControlLogix Platform

RSLogix 5000

Software

Kinetix 6500 Modular Multi-axis Servo Drive System

1585J-M8CBJM-x

Ethernet (shielded) Cable

1756-ENxTR EtherNet/IP Module

1734-AENT POINT I/O

EtherNet/IP Adapter

ControlLogix Controller Programming Network

1783-ETAP

Module

PowerFlex 755

Drive Module

2094-BMxx-M Axis Modules (5) with

2094-EN02D-M01-Sx Control Modules (5)

2094-BCxx-Mxx-M

Integrated

Axis Module

with

2094-EN02D-M01-Sx

Control Module

1585J-M8CBJM-OM3

0.3 m (1.0 ft) Ethernet cable

for drive-to-drive connections.