Troubleshooting the Kinetix 6200 and Kinetix 6500 Drive System

Chapter 8

Refer to the table on

page 188

for a description of the messages that scroll across

the display during powerup.

Table 79 - Four-character Display Messages

Drive Condition

Display String

Priority

Maximum
Number of
Messages
Displayed

Auxiliary Feedback Not
Configured as Feedback
Only

Auxiliary Feedback Configured as

Feedback Only

Axis 1

Axis 1

Axis 2

IP Address Display

(1)

IP = xxx.xxx.xxx.xxx

1

2

Sercos Node Address Display

(2)

Sercos NODE = xx

1

2

Safety Signature ID

(3)

SAFETY SIGNATURE = xxxxxxx

Firmware Upgrade

FIRMWARE UPDATE

2

2

Decelerating to a Stop as a Result of a Fault

ABORTING

Refer to footnote

(4)

Initialization Fault - Std. and Fault Code

(5)

INIT FLT Sxx

X1:INIT FLT Sxx

X2:INIT FLT Sxx

3

4

(6)

Initialization Fault - Mfg. and Fault Code

(5)

INIT FLT Mxx

X1:INIT FLT Mxx

X2:INIT FLT Mxx

Safety Fault

(5)

SAFE FLT xx

Refer to footnote

(4)

Node Fault

(5)

NODE FLT xx

Refer to footnote

(4)

Major Fault - Std. and Fault Code

(5)

FLT Sxx

X1:FLT Sxx

X2:FLT Sxx

Major Fault - Mfg. and Fault Code

(5)

FLT Mxx

X1:FLT Mxx

X2:FLT Mxx

Minor Fault - Std. and Fault Code

(5)

FLT Sxx

X1:FLT Sxx

X2:FLT Sxx

4

3

(7)

Minor Fault - Mfg. and Fault Code

(5)

FLT Mxx

X1:FLT Mxx

X2:FLT Mxx

Inhibit - Std. and Fault Code

(5)

INHIBIT Sxx

Refer to footnote

(4)

5

2

Inhibit Fault - Mfg. and Fault Code

(5)

INHIBIT Mxx

Refer to footnote

(4)

Safe Limited Speed

SAFE LIMITED SPEED

Refer to footnote

(4)

6

10

Power-up

(8)

‘BOOT’…’INIT’…’LOAD’…’DONE’…’BOOT’…’INIT’…’DONE’…‘LOAD’…’TEST’…FW Version: X.XXX

Waiting for CIP connection

STANDBY

Connecting

CONNECTING

Configuring Drive Attributes

CONFIGURING

Synchronizing

(1)

SYNCING

Waiting for DC-bus Up

PRE-CHARGE

Drive has been Shutdown

SHUTDOWN

Refer to footnote

(4)

Drive Axis has Stopped

STOPPED

Refer to footnote

(9)

Drive is Starting

STARTING

Refer to footnote

(4)

Drive is Running

RUNNING

Refer to footnote

(4)

Drive is Executing a Test Procedure

TESTING

Refer to footnote

(4)

Decelerating to a Stop as a Result of a Disable

STOPPING

Refer to footnote

(4)

Alarm Fault - Standard Fault Code

(5)

ALARM Sxx

X1:ALARM Sxx

X2:ALARM Sxx

Alarm Fault - Mfg. Specific Fault Code

(5)

ALARM Mxx

X1:ALARM Mxx

X2:ALARM Mxx

Node Alarm

NODE ALARM xx

Refer to footnote

(4)

(1) Applies to only 2094-EN02D-M01-Sx EtherNet/IP control modules.
(2) Applies to only 2094-SE02F-M00-Sx sercos control modules.
(3) Applies to only 2094-xx02x-M0x-S1 (safe-speed monitoring) control modules.
(4) Condition not supported by auxiliary feedback-only axis.
(5) A short descriptive string follows the displayed code.
(6) One node fault, two initialization, safety, major, or minor faults for axis 1, and one initialization, major, or minor fault for axis 2.
(7) One node fault, one initialization, safety, major, or minor faults for axis 1, and one initialization, major, or minor fault for axis 2.
(8) Text in single quotation marks, ‘BOOT‘ for example, is shown one word at a time (not scrolled).
(9) Condition not displayed.