External shunt module connections, Col int dc+ ts2 ts1 – Rockwell Automation 2094-EN02D-M01-Sx Kinetix 6200 and Kinetix 6500 Modular Multi-axis Servo Drives User Manual User Manual
Page 128

128
Rockwell Automation Publication 2094-UM002E-EN-P - May 2012
Chapter 5
Connecting the Kinetix 6200 and Kinetix 6500 Drive System
External Shunt Module
Connections
Follow these guidelines when wiring your external passive shunt module.
Figure 71 - Shunt Module Wiring
Figure 72 - Shunt Module Jumper Settings
(1) These are the default jumper settings.
IMPORTANT
When tightening screws to secure the wires, refer to the tables beginning on
page 102
for torque values.
IMPORTANT
To improve system performance, run wires and cables in the wireways as
established in
.
Use This
Shunt Module
Cat. No.
With This
Drive Module
Do This
Power rail mounted shunt
module.
2094-BSP2
N/A
• Verify the internal shunt jumper is in place between RC-2 and RC-3 (refer to
).
• Verify the thermal switch jumper is in place between TS-1 and TS-2 (refer to
).
External passive shunt
module connected to the
power rail shunt module.
1394-SRxxxx
2094-BSP2
Shunt module
• Remove the internal shunt jumper between RC-2 and RC-3.
• Remove the thermal switch jumper between TS-1 and TS-2
(if your shunt module includes a thermal switch).
• Refer to External Shunt Modules on
for noise zone considerations.
• Refer to Shunt Module Wiring Examples on
.
• Refer to the installation instructions provided with your Bulletin 1394 shunt module,
publication
.
1 2 3
1 2
1 2 3
1 2
COL
INT
DC+
TS2
TS1
COL
INT
DC+
TS2
TS1
External Shunt Resistor
(RC) Connector
Kinetix 6000 Shunt Module, Top View
(catalog number 2094-BSP2)
External Thermal Switch
(TS) Connector
Cable Shield
Clamp
Jumpers
(1)