Table 104 - Drive Behavior, SAFE FLT Fault Codes

Four-character Display Message

RSLogix 5000 Fault
Message

Description

CIP Motion and Sercos
Drive Behavior

SAFE FLT 01…INTERNAL HDWR nn

Internal Hardware

An internal hardware fault has been detected. On safe torque-off (-S0)
models, the nn sub-code is defined as follows:
01: Internal SPI communication fault.

02: Internal SPI write buffer overrun detected.

03: Internal SPI buffer write collision detected.

04: Internal SPI read buffer error detected.

05: Internal SPI read buffer overflow detected.

06: Internal SPI data integrity failure detected.

07: Internal watchdog time out reset occurred.

08: Internal stack overflow reset occurred.

09: Internal stack underflow detected.

10: Power supply brown out detected.

11: Over voltage monitor circuit test failure.

12: Under voltage monitor circuit test failure.

13: Error occurred during flash download.

14: Internal flash programming failure detected.

15: Safety firmware failed checksum verify.

16: Boot block is active.

Coast-Disable (open
contactor enable relay)

SAFE FLT 02…INVALID CONFIG

Invalid Configuration
Fault

One or more safety attributes have illegal values.

Coast-Disable

SAFE FLT 03…MP OUT nn

Motion Power Output
Fault

A fault has been detected on the motion power output circuitry. On safe
torque-off (-S0) models, the nn sub-code is defined as follows:
01: Gate power evaluation fault.

02: Gate enable evaluation fault.

Coast-Disable

SAFE FLT 04…RESET AT POWERUP

Reset at Powerup

The reset was detected as active at powerup.

Coast-Disable

SAFE FLT 05…FEEDBACK 1

Motor Feedback Fault

Feedback loss or an illegal state change has been detected on the motor AQB
inputs.

Coast-Disable

SAFE FLT 06…FEEDBACK 2

Auxiliary Feedback
Fault

Feedback loss or an illegal state change has been detected on the auxiliary
AQB inputs.

Coast-Disable

SAFE FLT 07…DUAL FB SPEED

Feedback Speed
Compare Fault

A speed miss-compare was detected between the two feedback devices.

Coast-Disable

SAFE FLT 08…DUAL FB POSITION

Feedback Position
Compare Fault

A position miss-compare was detected between the two feedback devices.

Coast-Disable

SAFE FLT 09…SS IN nn

SS Input Fault

The safe stop (SS) input circuitry has detected a problem. On safe torque-off (-
S0) models, the nn sub-code is defined as follows:
01: Input 0 failed pulse test.

02: Input 0 failed optocoupler test.

03: Input 1 failed pulse test.

04: Input 1 failed optocoupler test.

05: Input 3 failed optocoupler test.

06: Input 4 failed optocoupler test.

Coast-Disable

(1)

SAFE FLT 10…SS OUT nn

SS Output Fault

The safe stop (SS) output circuitry has detected a problem. On safe torque-off
(-S0) models, the nn sub-code is defined as follows:
01: Output 0 fault detected.

02: Output 1 fault detected.

Coast-Disable

(1)

SAFE FLT 11…DECELERATION

Deceleration Fault

The motor was detected to be not decelerating fast enough.

Coast-Disable

SAFE FLT 12…STOP SPEED

Zero Speed Fault

Zero speed was not detected by the end of the stop delay.

Coast-Disable