141

Configure and Start the Kinetix 6200 Drive System

Chapter 6

4. Set the sercos communication rate by using DIP switches 1 and 2.

5. Repeat

step 4

for each 2094-BM

xx-M axis module with 2094-SE02F-

M00-S

x control module.

IMPORTANT

When two or more IAM power modules are connected to the same
sercos interface module, each node address must be unique.

Refer to the node addressing examples beginning on

page 142

.

Setting

Switch

Switch Position

4 Mbps baud rate

SW2

ON

8 Mbps baud rate

(1)

(1) The Kinetix 6000M IDM system supports only 8 Mbps and is hardwired for this setting.

SW2

OFF

Low power light intensity

SW1

OFF

High power light intensity

SW1

ON

1

2

1

2

1

2

DIP Switches Set for

4 Mbps Applications

(high power setting)

DIP Switches Set for

8 Mbps Applications

(high power setting)

ON

OFF

Sercos Communication Rate

and Optical Power Switches

ON

OFF

Switch in ON Position

Switch in OFF Position

Kinetix 6200 IAM Power Module, Top View
with 2094-SE02F-M00-Sx Control Module