Delta RMC151 User Manual

Page 1019

Advertising
background image

9 Register Reference

Direct Output Halt

A Direct Output Halt is initiated.

See the Halts topic for details on the steps taken by the RMC when a Halt occurs.

Configuring the Auto Stops

To configure the Auto Stops:

Click the Axis Tools button on the RMCTools toolbar.

In the Axis Parameters pane, on the Setup tab, expand the Halts section and

expand the Auto Stop Configuration section.

Choose a halt type for each error bit.

Click the download button in the Axis Tools toolbar.

Why Bother?

A good system designer not only considers how a machine reacts in normal operation, but

also considers how it reacts when something fails. The Auto Stops help the designer avoid

personal injury or equipment damage when something does fail.
Example

A system designer decided to set all the Auto Stops to Status Only to avoid the hassle of

having the system stop when he was tuning it up. Unfortunately, the feedback

transducer on one of the hydraulic cylinders failed. The RMC thought the cylinder was at

0 inches when it really was at 20 inches.
The feedback error caused the RMC to apply full drive to the cylinder. The cylinder

slammed to the end of the stroke, smashing sensitive machine parts. This cylinder had

also been synchronized with another cylinder to push a machine part back and forth. Of

course, the cylinders went out of synchronization, bending the linkages between them.
If the Auto Stop for the No Transducer Error Bit and Transducer Overflow had been set

to Open Loop Halt, this accident could have been avoided. However, if it had been set to

Closed Loop halt, the accident would still have occurred, because a Closed Loop Halt still

requires feedback.

Format Details

This section is primarily for addressing the Auto Stops parameter when communicating

with the RMC from an external device. This information is not necessary when configuring

this parameter in RMCTools.
Each Auto Stop level is configured with 3 bits. These bits correspond to the Auto Stop

Levels as shown in the following table:

High
Bit

Mid
Bit

Low
Bit

Level

0

0

0

Status Only

0

0

1

External Halt

0

1

0

Closed Loop Halt

0

1

1

Open Loop Halt

1

0

0

Direct Output Halt

Auto Stop Bit Mapping

Register

Data

Type

Tag Name and Bits

%MD12.106 DWORD AutoStopCfg1.FollowErr

bits 0-2

Following

Error

-

bits 3-5

Reserved

deltamotion.com

999

Advertising
This manual is related to the following products: