8 Command Reference

Hardware Limitations: RMC75S: versions 2.1D or newer only

RMC75P: versions 2.1E or newer only
RMC75E: No limitations
RMC150E: No limitations


See the Commands Overview topic for basic command information and how to issue

commands from PLCs, HMIs, etc.

Command Parameters

# Parameter Description

Range

1 Offset (position-units)

any

2 Amplitude (position-units)

≥ 0

3 Frequency (Hz)

0* to 1/4 of the

loop frequency

4 Cycles

0 to 16 million in

0.25 steps (0 =

continuous)

5 Start Location

Auto (0)

Mid-Pos (1)

Pos Peak (2)

Mid-Neg (3)

Neg Peak (4)

a valid integer as

described

6 Status Block (address)

Note: See Specifying a Register Address below.

Address or none

(0)

*See the Frequency section below for details on the lower limit.

Description

This command starts a continuous sinusoidal move on a position axis. If the number of

cycles is specified, the sine move will end after completing the cycles and will hold

position. For pressure or force, use the Sine Start (Prs/Frc) (76) command.
Before issuing this command, the Target Position must be at the location specified by the

Start Location command parameter, or, a Transition command must previously have

been issued to specify how the axis should move to get to the sine curve. A transition

command will allow you to start a sine curve even though the axis is not at the correct

starting point.
If you want the axis to follow the sine curve exactly starting from the beginning, do not

use a transition; instead, make sure the axis is at the starting point before issuing the

Sine Start command.

Offset
The Offset specifies the position of the center of the sine wave.