Variable table - current values, Variable table - initial values – Delta RMC151 User Manual

Page 1131

Advertising
background image

9 Register Reference

RMC150 Registers, Files 56-59, 72-75: Variables Registers

All variable registers are Read/Write.
Tip:

For the DF1/CSP addressing format, all 'F' type registers (32-bit floating point) can also be

read as 'L' type (32-bit word) registers. This is very useful when reading variables defined as

DWORD or DINT data types.

AB
DF1,
CSP

Address

Modbus

TCP,RTU

Address

FINS
Address

External
Data

Type

Internal
I
EC

Address

Internal

Data

Type

Register Name

Variables - Current Values
F56:0-

255

28673-
29183

D28672-
D29182

*

%MD56.0-

255

*

Variables 0-255 - Current

Values

F57:0-

255

29185-
29695

D29184-
D29694

*

%MD57.0-

255

*

Variables 256-511 - Current

Values

F58:0-

255

29697-
30207

D29696-
D30206

*

%MD58.0-

255

*

Variables 512-767 - Current

Values

F59:0-

255

30209-
30719

D30208-
D30718

*

%MD59.0-

255

*

Variables 768-1023 -

Current Values

Variables - Initial Values
F72:0-

255

36865-
37375

E0_04096-
E0_04606

*

%MD72.0-

255

*

Variables 0-255 - Initial

Values

F73:0-

255

37377-
37887

E0_04608-
E0_05118

*

%MD73.0-

255

*

Variables 256-511 - Initial

Values

F74:0-

255

37889-
38399

E0_05120-
E0_05630

*

%MD74.0-

255

*

Variables 512-767 - Initial

Values

F75:0-

255

38401-
38911

E0_05632-
E0_06142

*

%MD75.0-

255

*

Variables 768-1023 - Initial

Values

* The data types of the variables are specified by the user when defining a variable in the

Variable Table.

Allen-Bradley DF1 and CSP
Where allowed by the host controller's communications, all the current values of the

variables can also be addressed as F56:n, up to n = 1023.
Modbus/TCP and /RTU
The address of the current value of variable n is 28673 + 2 x n.
FINS
The address of the current value of variable n is D28672 + 2 x n.

Note:

For the Modbus and FINS protocols, the command registers are duplicated in a lower

address area for PLCs that cannot access a wide range of registers. See the Modbus

Addressing and FINS Addressing topics for details.

Tag Names

Tag names are given to registers to be used when accessing the registers from within

RMCTools. Tag names make the project easy to read.

deltamotion.com

1111

Advertising
This manual is related to the following products: