RMC70/150 and RMCTools User Manual

Endpoint Behavior Truncate (+4)

Note: You can choose other Options settings, but these are typical.

4. Send the Curve Start Advanced (88) command. As specified by the Transition command,

the curve axis will move to the correct position on the curve, which is determined by the

location of the master axis. As the master axis moves in either direction, the curve axis

will follow the curve profile. If the master reaches the endpoints (ax defined by the first

and last x-value of the curve), it will behave as specified by the Endpoint Behavior in

the Options command parameter.

Curve Capacity

In RAM
The RMC can hold up to 128 curves in it's random-access memory, which is lost when

power is removed from the RMC. This curve storage capacity varies by RMC. The size

required for any curve also depends on the download method, data format, and

interpolation type. The following table gives approximate storage capacities for the

commonly used simple cubic-interpolated curve. See the Curve Storage Capacity topic for

more details.

Max Length for a

Single Curve

Max Length for 16

Equal-length

Curves

Max Length for 128

Equal-length

Curves

RMC75E
RMC150E

262,137 points

39,559 points

5,381 points

RMC75P
RMC75S

8,187 points

1,229 points

161 points

In Non-Volatile Memory
The RMC can store curves in non-volatile Flash memory, which is retained even when

power is removed from the RMC. Only curves downloaded from the Curve Tool or added

using the Curve Add command with the Permanent life cycle option are saved to flash.
The size consumed by curves in Flash is 8 bytes per point for Constant and Linear types,

and 16 bytes per point for Cubic types, plus 1 byte per character in the curve name and

description, plus approximately 40 bytes of overhead.
The curves share the same Flash storage as the entire RMC project, including axis

parameters, plot templates, variable table defaults, user programs, and curves. The total

Flash size is as follows:

Controller

Flash Size

RMC150E

1024 KB

RMC75E (1.1G and newer) 1024 KB
RMC75E (1.1F and older)

256 KB

RMC75P

96 KB

RMC75S

96 KB

Firmware and Hardware Requirements

Firmware and Hardware Requirements for Curves
Firmware
2.40 or newer.

3.38.0 or newer is required for the Curve Tool.

Hardware RMC150E: any version