Delta RMC151 User Manual

Page 429

Advertising
background image

6 Communication

your device supports reading and writing to registers in any of the PLCs listed below, then

your device should be able to communicate with the RMC:

Allen-Bradley SLC5/05 and PLC-5

The RMC emulates these controllers by responding to DF1 requests over the CSP and

EtherNet/IP protocols. See the CSP, EtherNet/IP, and DF1 Addressing topics for details.

Omron CS/CJ PLC

The RMC emulates these controllers by responding to requests over the FINS/UDP

protocol. See the FINS/UDP and FINS Addressing topics for details.

Modbus/TCP Controller

The RMC emulates a generic Modbus/TCP controller, responding to requests made over

Modbus/TCP. See the Modbus/TCP and Modbus Addressing topics for details.

Mitsubishi Ethernet Controller

The RMC emulates a Mitsubishi Ethernet controller listening for Procedure Exist

requests. See the Mitsubishi Procedure Exist Protocol topic for details.

Note: Even if your device cannot communicate with any of the above PLCs, it may still be able

to communicate with the RMC if it can make requests in any of the RMC’s supported industrial

Ethernet protocols. See the Supported Ethernet Protocols section in the Ethernet Overview

topic for details.

Instructions for Specific PLCs

Delta has provided instructions for setting up and using the following master Ethernet

controllers for communication with the RMC:

Allen-Bradley Controllers via Message Block

Allen-Bradley Controllers via EtherNet/IP I/O

AutomationDirect PLCs with the RMC

GE PLCs with the RMC

Mitsubishi Q-Series PLCs with the RMC

Omron PLCs via FINS

Omron PLCs via EtherNet/IP I/O

RSView with the RMC

Siemens S7 PLCs via PROFIBUS

Siemens S7 PLCs via PROFINET

Schneider Electric PLCs via EtherNet/IP I/O

Schneider Electric PLCs via Modbus

Online Examples

Delta has several example PLC and HMI programs for communicating with the RMC.

These examples will speed up your application development time. Refer to the Downloads

section of Delta's website at www.deltamotion.com.

Supported Ethernet Devices

Following is a partial list of devices that are known to communicate with the RMC:

Allen-Bradley Ethernet PLC-5 (1785-L20E, -L40E, or -L80E)

Allen-Bradley PLC-5 with the PLC-5 Ethernet Interface Module (1785-ENET)

Allen-Bradley Ethernet SLC 5/05

Allen-Bradley ControlLogix with Ethernet Interface Module (1756-ENET, 1756-ENBT,

1756-EN2T)

Allen-Bradley Ethernet CompactLogix (1769-L32E or 1769-L35E)

deltamotion.com

409