Delta RMC151 User Manual

Page 1102

Advertising
background image

RMC70/150 and RMCTools User Manual

only)

2 Rearm (Write

Only)

3 Read Active

(Read Only)

4 Trigger Enabled

(Read Only)

F38:1

19459

D19458 REAL

%MD38.1 UDINT Read/Write Plot Samples (e.g.

1000)

F38:2

19461

D19460 REAL

%MD38.2 REAL

Read/Write Plot Sample Period

(seconds)

F38:3

19463

D19462 REAL

%MD38.3 DINT

Read/Write Plot Axis Owner

0-3, -1 = none

F38:4

19465

D19464 REAL

%MD38.4 REAL

Read/Write Plot Trigger Position

%, 0-100, -1 =

auto rearm

F38:5

19467

D19466 REAL

%MD38.5 UDINT Read/Write Plot Trigger Type

0-

7

Trigger Type
(0=none,

1=motion

command)

8-

23

Depends on

trigger type
Motion

Commands:
8-

11

Axis 0-3 bits,

if all zero,

then use

Axis Owner

12-

23

Reserved

F38:6

19469

D19468 REAL

%MD38.6

-

-

Reserved

F38:7

19471

D19470 REAL

%MD38.7

-

-

Reserved

F38:8

19473

D19472 REAL

%MD38.8 REAL

Read Only Plot ID

F38:9

19475

D19474 REAL

%MD38.9 REAL

Read Only Plot State

0 = not triggered, 1

= capturing, 2 =

complete

F38:10

19477

D19476 REAL

%MD38.10 DINT

Read Only Plot Captured

Samples
Number of plot

samples captured.

Only applies for Plot

State > 0.

F38:11

19479

D19478 REAL

%MD38.11 DINT

Read Only Plot Sample 0 Time

Time that first plot

sample was

captured. In control

1082

Delta Computer Systems, Inc.