8 Command Reference

Hardware Limitations: RMC75S: versions 2.1D or newer only

RMC75P: versions 2.1E or newer only
RMC75E: No limitations
RMC150E: No limitations


See the Commands Overview topic for basic command information and how to issue

commands from PLCs, HMIs, etc.

Command Parameters

# Parameter Description

Data Type

Range

1 Curve ID

Internal:

DINT
External:

REAL

0-50000

2 Curve Data (address)

Note: See Specifying a Register

Address below.

REAL

any Variable

Table

address

3 Interpolation Method

Constant (0)

Linear (1)

Cubic (2) - default

REAL

a valid

integer as

described

4 Life Cycle

Standard (0) - default

Start-Once (1)

Complete-Once (2)

Permanent (3)

REAL

a valid

integer as

described

Description

This command is used for creating curves in the RMC from a PLC, PC, or even from user

programs. For details on the procedure, see Creating Curves Using the Curve Add

Command. This command is not necessary when creating curves in the Curve Tool. Once

the curve data has been written to the Variable Table, sending this command will create

the curve in the RMC.
Once a curve has been created, it can be viewed in the Curve Tool, and can be used with

the Curve Start (86) or Curve Start (Prs/Frc) (87) command for a time-based profile or

camming based on a master.
Creating a curve requires some processing time that typically exceeds one loop time. It is

important to not start a curve before it has been processed and added to the Curve Store.

The RMC will report the state of the Curve Add in the Curve Status register, which is

part of the Curve Data.
For more details, refer to the Creating Curves Using the Curve Add Command topic.
Curve ID
This provides a way of identifying the curve. This can be any number from 0 to 50,000.

The ID will be used in the Curve Start (86) and Curve Start (Prs/Frc) (87) commands to

specify which curve to start. A maximum of 128 curves can be stored in the Curve Store,

although each ID can be from 0 to 50,000. For the Multiple Curves format, the curves will

receive sequential IDs beginning with this Curve ID.
If a curve with the requested ID already exists, the existing curve will be deleted and the

new curve with that ID added.