background image

RMC70/150 and RMCTools User Manual

1 = Slave - Clock is an

input

F144+n:17 73741

+512 x n

E1_08204

+512 x n

DWORD %MD144+n.17 DWORD Read/Write Channel 0 SSI Options

Applies only to SSI

Output and SSI Register

Input modes]
Bit 0-5 - SSI Data Bits
Range: 8-32
Bit 6 - SSI Encoding
0=Binary, 1=Gray Code
Bit 8 - Terminate

Inputs
[Applies to all SSI Output

and SSI Register Input

modes except SSI Output

- Master.]
SSI Register Input -

Standard: Data Inputs
SSI Register Input -

Monitor: Clock/Data

Inputs
SSI Output - Slave: Clock

Inputs
Bit 16-31 - SSI Clock

Rate (kHz)
Specifies the clock rate in

kHz. The actual rate will

be determined by the

available integer divisor

(16500/SSIClockRatekHz-

1). Initial supported

values are 250, 500, and

971, with the default of

250 kHz.

F144+n:18 73743

+512 x n

E1_08206

+512 x n

DINT

%MD144+n.18 DINT

Read/Write Channel 0 Wire Delay

[Applies only to SSI

Register Input modes]
Time to delay (ns) from

Clock to Data. This value

will be converted to the

nearest time delay that

can be represented with

[1..8] * [0..31] / 33MHz.

F144+n:19 73745

+512 x n

E1_08208

+512 x n

DWORD %MD144+n.19 DWORD Read/Write Channel 0 Source/Dest

[Applies only to SSI

Output and SSI Register

Input modes]
For SSI Output mode,

this is the address of the

register to send out the

SSI Output. Ignored if

Echo is enabled. For SSI

Register Input, this is the

1122

Delta Computer Systems, Inc.

Advertising