Delta RMC151 User Manual

Page 533

Advertising
background image

6 Communication

14

Float*

Explicit Read Data 5

15

Float*

Explicit Read Data 6

*These registers are typically REAL data type (floating point), but in some cases may be

DINT or DWORD integers, such as variables declared as such.
Consistent and Non-Consistent Registers
Registers 0-7 of the Response Block are consistent. That is, they are all updated at the

same time. These registers are suitable for tight synchronization with the commands,

read/write requests, or each other.
Registers 8-15 of the Response block are non-consistent. That is, each register is not

guaranteed to be updated at the same time as the other registers in the block, nor at the

same time as the registers in the first Response Block. They are updated at the same rate

as the first Response block, but each register's update may differ slightly.
Because they are non-consistent, registers 8-15 should not be used for tight

synchronization. The following registers should not be placed in Indirect Data Map

registers 8 to 15 so that they will not be in registers 8-15 of the Response Block:

Read Response register

Status and Error bits, because these bits are often checked immediately after a

command is issued.

Configuring the Data

Setting up the Indirect Data Map
The Response Block continuously returns the values from the RMC70 Indirect Data

registers 0-7. These registers, in turn, can be mapped to any registers in the RMC70.

Thereby, the values from the selected registers in the RMC70 can be read from and

written to by writing to and reading from the Indirect Data registers.
To set up the Indirect Data Map:

1. Open the Indirect Data Map Editor.
2. In the Register column of the first Indirect Data Map entry, type "%MD8.0" and press

Enter. This will map Axis 0 Status Bits register to the first item in the Indirect Data

Map. Basic mode requires that the first item in the Indirect Data Map contains the Axis

0 Status Bits register.

3. For each of the remaining Indirect Data Map entries 1-7, enter the desired register to

map to each. To do this, click the cell in the Register column, click the ellipsis button
( ), then browse to the desired register.

4. If you wish to add additional read capability, one of the Indirect Data Map registers

should be mapped to the Read Response register. Then, the corresponding register in

the Response Block will return the value of a read from any single register in the

RMC70 at any time. See Read any Single RMC70 Register below. Notice that this is

probably unnecessary because this mode already enables you to read from seven

contiguous registers. See Read any Contiguous RMC70 Registers below.


Example

Requirements
The user would like to read the following registers:

Axis 0 Status Bits

Axis 0 Actual Position

Axis 1 Status Bits

Axis 1 Actual Position

Task 0 Current Step