Delta RMC151 User Manual

Page 794

Advertising
background image

RMC70/150 and RMCTools User Manual

Command Parameters

# Parameter Description

Data Type

Range

1 Curve ID

Internal:

DINT
External:

REAL

0-50000

2 Master Register

Note: See Specifying a Register

Address below.

REAL

_Time or any

other valid

register of

type REAL.

3 Cycles

0 = continuous,
1 = 1 cycle
n = n cycles (up to 16 million)

REAL

0 to 16

million
(0 =

continuous)

4

Options, sum of the following:

Curve Alignment, one of:

Absolute Curve Alignment (+0)
Relative Curve Alignment (+1)

Master Alignment, one of:

Relative Master Alignment (+0)
Absolute Master Alignment (+2)

Endpoint Behavior

For Absolute Master alignment,

one of:

Fault (+0)
Truncate (+4)
Extrapolate (+8)

For Relative Master alignment,

one of:

Standard (+0)
Truncate (+4)
Truncate and End (+8)

Internal:

DINT
External:

REAL

≥ 0, whole

numbers

5

Curve Scale

REAL

any

6

Curve Offset

REAL

any

7

Master Scale

REAL

≠ 0

8

Master Offset

REAL

any

9

Status Block (address)
Note: See Specifying a Register

Address below.

REAL

Address or
none (0)

Description

This command is identical to the Curve Start (86) command, but with additional advanced

options such as offsetting or scaling the y-axis of the curve, offsetting or scaling the curve

master, choosing absolute or relative curve alignment or master alignment, and the

inclusion of a status block for advanced status information.
Notice that the command parameters do not change the curve itself in the RMC. It only

defines the instance of the curve that is started with this command.

774

Delta Computer Systems, Inc.

Advertising
This manual is related to the following products: