Input termination parameter, Input termination, Input – Delta RMC151 User Manual

Page 954: Termination

Advertising
background image

RMC70/150 and RMCTools User Manual

RMC70 Address: Primary Input: %MDn.10/0-2, where n = 12 + the axis number

Secondary Input: %MDn.28/0-2, where n = 12 + the axis number

RMC150 Address: Primary Input: %MDn.10/0-2, where n = 24 + the axis number

Secondary Input: %MDn.28/0-2, where n = 24 + the axis number

System Tag: Primary Input: _Axis[n].AnalogCfg.InputRange

Secondary Input: _Axis[n].SecAnalogCfg.InputRange

How to Find: Axes Parameters Pane, Setup tab: Primary Control Setup

Axes Parameters Pane, Setup tab: Secondary Control Setup

Data Type: Bits

Range: ±10V (0), 4-20mA (1), ±5V (2)

Default Value: Voltage (±10V) (0)

Description

The Analog Input Type register specifies the type of analog feedback from the transducer:

±10V

If the feedback is voltage, choose this option.

±5V (RMC150 A and H modules only)

If you are using an input on the RMC150 A or H modules, and the analog input voltage

does not exceed ±5V, choose this option for higher resolution.

4-20 mA

If the feedback is 4-20 mA, choose this option.


The input types of differential force or differential acceleration inputs must be identical

and are determined by a single parameter.
Notice that voltage and current require different wiring.
Changing this Parameter
Because this parameter affects motion, the axis must be disabled or in Direct Output

before writing to this parameter. The Enabled and Direct Output Status Bits indicate these

states of the axis. When changing this parameter from RMCTools, the software will

automatically do this for you.

Format Details

This section is primarily for addressing the Analog Input Type parameter when

communicating with the RMC from an external device. This information is not necessary

when configuring this parameter in RMCTools.

Bit 2 Bit 1 Bit 0 Value Control Mode

0

0

0 0

±10V

0

0

1 1

4-20mA

0

1

0 2

±5V (RMC150 Only)


See the Analog Configuration Register topic for details about the register containing these

bits.

9.2.2.2.23.14. Input Termination Parameter

Type: Axis Parameter Register

934

Delta Computer Systems, Inc.

Advertising