Delta RMC151 User Manual

Page 153

Advertising
background image

3 Controller Features

and Y values, allowing variable spacing.
(22) Partial Curve - Advanced Points
This partial curve format expands on the Variable-Spaced Points

format by allowing the velocity to be set at any point, and constant-

velocity segments to be specified.

Single Curve - Evenly-Spaced Points

This is the simplest method. The spacing of the X values is constant. The X value for each

point is defined as X

i

= X

0

+ ΔX·i. This method does not support fixing velocities at any

point or constant-velocity segments on cubic interpolated curves, except as defined by

the selected Interpolation Options.

Note: Data types are all REAL.

Offset Register

Description

0 Status

See Above

1 Format

(0) Single Curve - Evenly-Spaced Points

2 PointCount

Number of points in the curve (N). The minimum number of

points is 2.

3 InterpOpt

Interpolation Options. See the Curve Interpolation Methods

and Options topic for details.

+0: Zero-Velocity Endpoints
+1: Natural-Velocity Endpoints
+2: Cyclic Curve
+8: Overshoot Protection
+16: Auto Constant Velocity

4 X

0

Point 0 X value
This value is only used when following a curve with absolute

master alignment (only available with the Curve Start

Advanced (88) command).
This value is not used when following a curve using the

Curve Start (86) or Curve Start (Prs/Frc) (87) comamnds;

the X

0

point is the current value of the master at the time

the command is issued. The remaining X-axis points are

computed relative the master position when the Curve Start

command is issued.

5 X Interval

(ΔX)

Interval in X between Points

6 Y

0

Point 0 Y value

7 Y

1

Point 1 Y value

: :

:

6+(N-1) Y

N-1

Point N Y Value

Single Curve - Variable-Spaced Points

In this format, points are each given independent X and Y values—allowing variable

spacing—but does not support fixing velocities or specifying constant-velocity segments

on cubic interpolation, except as defined by the selected Interpolation Options. The X

values must be increasing (X

i+1

> X

i

).

Note: Data types are all REAL.